Welcome to the 广东凯宝机器人科技有限公司
ABOUT US

Technical
Basic knowledge Fault handling maintenance documents
  

During the use of frequency height, please shorten the periodic inspection and maintenance cycle:

Check:●  Maintenance: ◎

[recommended use of lubricating oil type: AFEP2 or NSK LG LG - 2 non-dust room dedicated thread guide lubricant]


Part name Before and after operation Every 3 months Every 6 months Every year Key maintenance Exception handling
Power line, signal line       ●Check the power line, the signal line whether break, break, etc ●Bad ones need to be replaced
Screw, nut, bearing ●◎ ●◎ ●◎ ●Check for normal vibration and noise
◎Check the rod for lubricating oil
●Confirm whether there is dirt, if there is remove dirt and refill oil;
◎Please refill the oil if there is no or too little
Dust-proof strip ●Confirm whether the steel band is damaged
●Confirm whether the steel belt is loose
●If the function is affected, it needs to be replaced
●If it is loose, it will need to be recalibrated and tightened
guide ●◎ ●◎ ●◎ ●Whether the guide screw is loose
●Whether there is a noise when the platform moves
◎Slide block, guide rail add lubricant
●Reset the lock screw
●Confirm whether there is dirt, if there is remove dirt and refill oil;
All the screws   ●Check for loose ●Reset the lock screw
Sliding table ●◎ ●◎ ●◎ ●Is there any difference in the sliding table
●Is the platform loose
●Confirm whether there is dirt, if there is remove dirt and refill oil;
●Loose will need to be recalibrated and tightened